Keyword      Search in       

Contact
Imprint
Site Map

RSS Feed News. Your shopping cart.

Google gadget.

GMP News
27/01/2010
 

FDA Publishes Statement on the Frequency of Media Fills

  
Question: What is the acceptable media fill frequency in relation to the number of shifts? Normally, media fills should be repeated twice per shift per line per year. Is the same frequency expected of a process conducted in an isolator?

According to FDA's principles, the frequency of media fills should be fixed in relation to the shifts on the basis of a risk assessment. In traditional aseptic filling, one media fill per shift per half year is expected. On a line with 2 shifts, this requires at least 4 media fill runs. For a closed and highly automated system over several shifts, however, the number of media fill runs can be reduced in case of a rigorous media fill design. Isolators and closed-vial filling are expressly mentioned as closed systems; but RABS (Restricted Access Barrier System) are expressly excepted from this group. A semi-annual media fill per line is still expected; however, the absolute number of media fill runs can be reduced based on a sound risk rationale under certain circumstances. Here you can read the FDA's answer.

Author:
Dr Andreas Mangel
On behalf of the European Compliance Academy (ECA)

Source: FDA Webpage, Questions and Answers on Current Good Manufacturing Practices, Good Guidance Practices, Level 2

Related GMP News
01/09/2010New WHO Draft on the Manufacture of Sterile Medicinal Products
01/09/2010Inspection of Biological Drug Products
04/08/2010New draft of ISO 14644-9 - Classification of Surface Cleanlinesss
14/07/2010USP 1050 Viral Safety of Biotechnology Products Derived from Cell Lines of Human or Animal Origin - proposed Revision
16/06/2010FDA Guideline to Reduce the Risk of Transmission of CJD and vCJD by Blood and Blood Products